SAFElife

14 Panel T-Cup Urine Multi-Drug Test with EtG & Fentanyl, FUO

$159.00

SAFElife 14 Panel T-Cup Urine Multi-Drug Test with EtG & Fentanyl is an all-in-one, self-contained urine collection and screening cup for professional forensic drug-testing programs. Its larger-mouth T-Cup design supports convenient specimen collection, while integrated test strips, a temperature indicator, and easy-read result windows help streamline on-site screening. This 14-panel configuration includes ethyl glucuronide (EtG) and fentanyl for expanded monitoring needs. Each box contains 25 forensic-use test cups.

Product Specifications

Brand SAFElife
SKU TDOA-8145EF
Test Format T-Cup urine multi-drug test cup
Detectable Drugs AMP1000-BAR300-BUP10-BZO300-COC300-ETG500-FTY20-MAMP1000-MDMA500-MOP300-MTD300-OXY100-PCP25-THC50
Specimen Type Urine
Result Time Read at 5 minutes
Temperature Check 90–100°F acceptable; observe temperature strip between 2 and 4 minutes after collection
Quantity 25 test cups per box
Result Display Line-based
Test Method Rapid diagnostic test (RDT); point-of-care test
Classification Forensic Use Only
Intended Setting Professional forensic, correctional, workplace, and point-of-care screening programs

Key Features

  • 14-panel urine drug screen with EtG and fentanyl: Screens for amphetamine, barbiturates, buprenorphine, benzodiazepines, cocaine, ethyl glucuronide, fentanyl, methamphetamine, MDMA, morphine/opiate compounds, methadone, oxycodone, phencyclidine, and marijuana/THC.
  • EtG and fentanyl screening included: Adds alcohol-metabolite and fentanyl screening to a broad urine drug-test panel.
  • All-in-one T-Cup design: Combines urine collection and on-site drug screening in one self-contained device.
  • Larger collection mouth: Supports easier specimen collection and can help reduce spills.
  • Integrated temperature strip: Supports specimen-temperature verification between 2 and 4 minutes after collection.
  • 90–100°F temperature range: An in-range temperature supports an acceptable specimen-temperature check.
  • Minimum-fill line: Helps confirm the specimen reaches the required collection level.
  • Peel-away result label: Provides access to easy-to-read, line-based result windows after collection.
  • Rapid results: Provides preliminary screening results at 5 minutes.
  • Forensic Use Only: Intended for forensic-use testing programs; not for diagnostic use.
  • 25 test cups per box: Supports routine professional and forensic screening programs.

Simple Test Procedure

  1. Collect the urine specimen directly in the test cup, ensuring it reaches the minimum fill line.
  2. Recap the cup securely and place it on a clean, flat surface.
  3. Observe the integrated temperature strip between 2 and 4 minutes after collection. A temperature of 90–100°F is acceptable; other readings may indicate a specimen-integrity concern.
  4. Peel back the result label to expose the test-result window.
  5. Read and interpret the drug-screen results at 5 minutes.

How to Interpret Results

Urine drug test result interpretation guide A positive result displays one control line. A negative result displays control and test lines, including a faint test line. An invalid result has no control line. C T POSITIVE C T NEGATIVE ** Faint line C T INVALID
Result interpretation: A positive result shows one control line (C). A negative result shows both the control line (C) and test line (T); a faint test line is still negative. A result is invalid when no control line appears.

Important: No meaning is attributed to test-line color, intensity, or width. A faint test line is still interpreted as a negative result. This screening device provides preliminary results only; follow applicable program procedures for confirmation of presumptive positive results.

Frequently Asked Questions

What does this 14-panel T-Cup test detect?

This configuration screens for amphetamine (AMP), barbiturates (BAR), buprenorphine (BUP), benzodiazepines (BZO), cocaine (COC), ethyl glucuronide (EtG), fentanyl (FTY), methamphetamine (MAMP), MDMA, morphine/opiate compounds (MOP), methadone (MTD), oxycodone (OXY), phencyclidine (PCP), and marijuana/THC.

What are EtG and fentanyl tests used for?

EtG is an alcohol-metabolite marker, while fentanyl is a synthetic opioid analyte. Both are included as dedicated screening strips in this test configuration.

How many test cups are included per box?

Each box contains 25 individual 14-panel T-Cup urine drug test cups.

When should results be read?

After collecting the specimen, securely recapping the cup, and peeling back the result label, read and interpret results at 5 minutes.

How is specimen temperature checked?

Observe the integrated temperature strip between 2 and 4 minutes after collection. A temperature reading from 90–100°F is acceptable.

What does a faint test line mean?

A faint test line is interpreted as a negative result. Test-line color, intensity, and width do not change result interpretation.

Shipping & Returns

Most of our products ship free within the contiguous United States on orders over $100.

Please note that free shipping is not available for deliveries to Canada, Alaska, Hawaii, or any U.S. territories.*

Cutoff Levels • Detection Periods • Product Inserts

Order in Bulk. Save Big. It’s That Simple.     

800-652-3502