SAFElife
10 Panel T-Cup Urine Multi-Drug Test with 3 Adulterants, CLIA Waived
SAFElife 10 Panel T-Cup Urine Multi-Drug Test Cup with 3 Adulterants is an all-in-one, self-contained urine collection and screening cup for professional point-of-care drug-testing programs. The larger-mouth T-Cup design supports convenient specimen collection, while integrated test strips, a temperature indicator, and easy-read result windows help streamline on-site screening. This configuration detects 10 drug classes and includes built-in adulteration checks for creatinine, pH, and specific gravity. Each box contains 25 FDA 510(k)-cleared, CLIA-waived test cups.
Product Specifications
| Brand | SAFElife |
|---|---|
| SKU | TDOA-3104A3 |
| Test Format | T-Cup urine multi-drug test cup with adulteration checks |
| Detectable Drugs | AMP1000-BAR300-BZO300-COC300-MAMP1000-MDMA500-MTD300-OPI2000-PCP25-THC50 |
| Adulterant Checks | Creatinine (CR), pH, and Specific Gravity (SG) |
| Specimen Type | Urine |
| Result Time | Read at 5 minutes |
| Temperature Check | 90–100°F acceptable; observe temperature strip between 2 and 4 minutes after collection |
| Quantity | 25 test cups per box |
| Result Display | Line-based |
| Test Method | Rapid diagnostic test (RDT); point-of-care test |
| Classification | FDA 510(k) Cleared and CLIA Waived |
| Intended Setting | Professional workplace, clinical, occupational-health, correctional, forensic, and point-of-care screening programs |
Key Features
- 10-panel drug screen with adulteration checks: Screens for amphetamine, barbiturates, benzodiazepines, cocaine, methamphetamine, MDMA, methadone, opiates, phencyclidine, and marijuana/THC, plus creatinine, pH, and specific-gravity checks.
- All-in-one T-Cup design: Combines urine collection and on-site drug screening in one self-contained device.
- Larger collection mouth: Supports easier specimen collection and can help reduce spills.
- Integrated temperature strip: Supports specimen-temperature verification between 2 and 4 minutes after collection.
- 90–100°F temperature range: An in-range temperature supports an acceptable specimen-temperature check.
- Adulteration detection support: Creatinine, pH, and specific-gravity checks add specimen-validity information beyond temperature alone.
- Minimum-fill line: Helps confirm the specimen reaches the required collection level.
- Peel-away result label: Provides access to easy-to-read, line-based drug-screen and adulterant result windows after collection.
- Rapid results: Read preliminary drug-screen and adulterant results at 5 minutes.
- FDA 510(k)-cleared and CLIA-waived: Designed for eligible professional point-of-care testing settings.
- 25 test cups per box: Supports routine workplace, clinical, forensic, and occupational-health screening programs.
Simple Test Procedure
- Collect the urine specimen directly in the test cup, ensuring it reaches the minimum fill line.
- Recap the cup securely and place it on a clean, flat surface.
- Observe the integrated temperature strip between 2 and 4 minutes after collection. A temperature of 90–100°F is acceptable; other readings may indicate a specimen-integrity concern.
- Peel back the result label to expose the drug-screen and adulterant result windows.
- Read and interpret the drug-screen and adulterant results at 5 minutes.
How to Interpret Results
Important: No meaning is attributed to test-line color, intensity, or width. A faint test line is still interpreted as a negative result. This screening device provides preliminary results; follow applicable program procedures for confirmation of presumptive positive results. Interpret adulterant-check results according to the product instructions and your testing program procedures.
Frequently Asked Questions
What drugs does this 10-panel T-Cup test detect?
This configuration screens for amphetamine (AMP), barbiturates (BAR), benzodiazepines (BZO), cocaine (COC), methamphetamine (MAMP), MDMA, methadone (MTD), opiates (OPI), phencyclidine (PCP), and marijuana/THC.
What are the three adulterant checks?
This test includes creatinine (CR), pH, and specific gravity (SG) checks to provide additional specimen-validity information and help identify abnormal or potentially adulterated urine specimens.
How is specimen temperature checked?
Observe the integrated temperature strip between 2 and 4 minutes after collection. A temperature reading from 90–100°F is acceptable.
When should results be read?
After collecting the specimen, securely recapping the cup, and peeling back the result label, read and interpret the drug-screen and adulterant results at 5 minutes.
How many test cups are included per box?
Each box contains 25 individual 10-panel T-Cup urine drug test cups with three adulterant checks.
What does a faint test line mean?
A faint test line is interpreted as a negative result. Test-line color, intensity, and width do not change result interpretation.
Shipping & Returns
Most of our products ship free within the contiguous United States on orders over $100.
Please note that free shipping is not available for deliveries to Canada, Alaska, Hawaii, or any U.S. territories.*